Click here for a rep to call  Click here for product information 01202 658444
FAIL (the browser should render some flash content, not this).
Ophthalmic products

 
 


croma pharma silicone oils perfluorcarbons tubing sets vitreoretinal posterior segment

croma pharma silicone oils perfluorcarbons tubing sets vitreoretinal posterior segment


The Widest range of PreLoaded Injector Systems and lenses in the market.

The Click Click press system has been tried and tested successfully throughout Europe for the last four years.


BARRETT IOL Pre loaded
aspira

BARRETT IOL Pre loaded 

In cooperation with Prof. Graham Barrett (Perth, Australia), CROMA developed BARRETT IOL, a single-piece hydrophilic pre-loaded IOL featuring an innovative and so far unique design of the haptics:

Even under decreasing diameters of the capsular bag BARRETT IOL optimally disperses the forces of the haptics onto the capsular bag. Therefore, damage of the capsular bag can be widely avoided compared to other IOLs featuring common C-loop haptics.

BARRETT IOL optimally adapts to all sizes of the capsular bag and guarantees best posterior projection as well as increased stability inside the capsular bag.

Specification:

-Single-piece Hydrophilic acrylic 26%
-Optic diameter: 6 mm
-Overall diameter: 13 mm
-360° square edge
-Implantation: capsular bag
-Recommended A-constant: 1119.5 (SRK-T,US-biometry)
-Angulation: 6°
-Available from +10.0 Dto +30.0 D
-Incision: pre-loaded injector for small incision

Advantages:

-Pre-loaded IOL in an innovative single-use injector for small incision
-Unique optic-design for excellent visual acuity
-Designed to fit all capsular bag diameters
-360° square edge to avoid cell migration

-Special design of the haptics for excellent centration in the capsular bag


 
QUATRIX® Aspheric Evolutive pre-loaded

QUATRIX¬Æ Aspheric Evolutive pre-loaded 

The basic principle of QUATRIX® Aspheric Evolutive pre-loaded respects the peculiar physiological need for individual IOL diameters.

The overall diameter of QUATRIX® Aspheric Evolutive pre-loaded decreases linear according to the increasing diopter size of the IOL.

The individual size for the individual eye!

- One-piece Hydrophilic acrylic
- Optic diameter: 5,85 mm - 6,15 mm
- Optic profile: Square edge (360°)
- Overall diameter: 10.3 mm for P 30 to 10.8 mm for P 10
- Implantation: capsular bag
- Angulation: 6°
- A-Constant: 119.3 (SRK T)

- Available diopter range: +10D to +30D (0.5)


 
EYE-Cee Pre-loaded
EYE-Cee Pre-loaded

With EYE-Cee CROMA presents a new hydrophobic IOL in an innovative pre-loaded injector for single-use.

Due to the innovative single-use pre-loaded injection system, which facilitates the work of the surgeon tremendously and fully prevents the lens from damage or bacterial contamination

Specification:

3-piece IOLHydrophobic soft acrylic, PMMA haptic
Optic diameter: 6.0 mm
Overall diameter: 12.5 mm
Optic propile: square edge (360°)
Implantation: capsular bag
Recommended A-constant: 119.2 (nominal)
Angulation: 7°
Available: from +10.0D to 27.0 D (0.5 D increments),
        from 27.0 to 28.0 D (1.0 D increments)
UV-filter
Incision: pre-loaded injector for 2.8 mm

Advantages:

Pre-loaded injection system for safe and easy handling
Damage of the implant is avoided
No risk of dangerous cross-contaminations

360° square edge for prevention of PCO

 

 

 



Croma Pharma - BARRETT IOL, QUATRIX®, EYE-Cee

For further information please contact us



 
Privacy Policy
Home Page   |   Our Company   |   Products   |   News and Events   |   Contacts Us